Menu

MEP Trades

Commercial Plumbing Estimating Services

Tribuild takes off plumbing by system: fixtures counted, and domestic water, sanitary, vent, storm, and gas piping measured by size and linear foot, with equipment, valves, and supports carried so your bid follows the drawings.

Plumbing is a system takeoff, not a per-fixture guess. Tribuild counts fixtures from the schedule with carriers and trim, then measures domestic water, sanitary, vent, storm, and gas piping by size and linear foot from the plans and risers, so each system is quantified from the drawings.

Equipment, valves, specialties, and supports are carried per the schedules, site connections are coordinated with the utility scope, and every deliverable ships with documented assumptions your team can price and defend.

What we estimate for plumbing

Plumbing fixtures

Fixtures counted by type from the fixture schedule with carriers and trim.

Domestic water

Hot and cold water piping by size and linear foot with fittings.

Sanitary piping

Sanitary waste piping by size and linear foot from plans and risers.

Vent piping

Vent piping by size and linear foot.

Storm piping

Storm and overflow piping by size and linear foot with roof drains.

Natural gas

Gas piping by size and linear foot with regulators and valves.

Medical gas

Medical gas piping and outlets counted where applicable (healthcare scope).

Plumbing equipment

Water heaters, pumps, and specialties counted by unit.

Valves

Isolation, balancing, and specialty valves counted by type and size.

Supports

Hangers, supports, and seismic bracing by allowance/linear foot.

Insulation

Pipe insulation by size and linear foot where in the plumbing scope.

Specialty plumbing systems

Acid waste, RO/DI, and specialty systems counted where applicable.

Site connections

Building-to-5-foot site connections coordinated with the utility scope.

Demolition

Removal of existing plumbing quantified for disposal.

Services available for this trade

What you receive

  • Quantity takeoff workbook by plumbing system
  • Fixture counts by type with carriers and trim
  • Piping by system, size, and linear foot
  • Equipment, valve, and specialty counts
  • Insulation and support allowances
  • Scope notes, assumptions, and qualification notes

Software and platforms

Trimble AutoBid MechanicalTrimble Estimation MEPRevitBluebeamAutoCADFastPIPEQuoteSoft PipeTrimble SysQuePypeServerAutodesk Fabrication CADmep

Project experience

HealthcareEducationCorporate officesHospitalityMultifamilyIndustrialGovernment

How it works

  1. 1

    You submit drawings, specifications, addenda, and bid information, and book your call in the same step.

  2. 2

    The project is assigned to the appropriate estimator or team, and questions and clarifications are documented where necessary.

  3. 3

    The deliverable is reviewed under Tribuild's applicable quality-control process and delivered before your call.

  4. 4

    On the call we review the completed deliverable together and capture the formats and process your team needs.

  5. 5

    You choose how you engage us: per project, hourly, per square foot, per dedicated estimator, or a monthly or annual SLA.

  6. 6

    You are set up on the Tribuild portal with a dedicated point of contact and a POC email address for day-to-day communication.

  7. 7

    Scope changes and preferences are recorded continuously in your Scope of Work, which stays live in the portal, and revisions and addenda are managed under the applicable service agreement.

Quality control

  • Systems reconciled against plumbing plans, risers, and the fixture schedule
  • Piping measured by system and size
  • Fixtures and equipment counted from schedules
  • Site connections coordinated with the utility scope
  • Addendum tracking against plumbing revisions

Proven results

Frequently asked questions

Plumbing plans and riser diagrams, the fixture schedule, equipment schedules, and specifications. Risers help us measure vertical piping correctly.

Yes, fixtures are counted by type from the schedule with carriers, trim, and rough-in so the full fixture scope is priced.

Yes, where applicable on healthcare projects, medical gas piping and outlets are counted per the documents.

By system and size in linear foot from plans and risers, with fittings and valves counted, not estimated as a per-fixture assembly.

Yes, always. Color-coded PDFs and Excel workbooks are standard, and the native source files are included with every deliverable.